A Cross-Sectional Analysis: Role of Shear Wave Elastography in Diagnostic Imaging of Normal and Abnormal Testis
1
Lecturer, Department of Radiology and Imaging Sciences, Meenakshi Medical College Hospital and Research Institute (MMCHRI), Meenakshi Academy of Higher Education and Research (MAHER) deemed to be a University, Tamil Nadu, India.
2
Professor, Department of Radiology and Imaging Sciences, Meenakshi Medical College Hospital and Research Institute (MMCHRI), Meenakshi Academy of Higher Education and Research (MAHER) deemed to be University, Tamil Nadu, India.
3
Dean, Meenakshi Medical College Hospital and Research Institute (MMCHRI), Meenakshi Academy of Higher Education and Research (MAHER) deemed to be University, Tamil Nadu, India.
Received: 2025-04-10
Revised: 2025-05-14
Accepted: 2025-06-05
Published: 2025-07-08
A non-invasive, quantitative imaging modality, which is an evaluation of tissue stiffness, is Shear Wave Elastography (SWE). Although it has been standardised in the assessment of the liver and thyroid gland, its application in testicular imaging is still being research. This paper sought to analyse the usefulness of SWE in the diagnosis of normal and abnormal testis, in the diagnostic imaging process, as well as to determine normal baseline values of elasticity in clinical applications. A cross-sectional research study was conducted in the Department of Radiology and Imaging in the Meenakshi Medical College Hospital and Research Institute. Fifty male patients (comprising 100 testes), some healthy volunteers, and those with abnormalities of the scrotum were studied with SWE with a high-frequency linear transducer (5 12 MHz). Testis were grouped into normal, hydrocele, varicocele and other abnormalities. Measurements of quantitative stiffness (kPa) were taken separately on the testicular parenchyma and hilum. Parenchymal stiffness of the normal testis was 3.8 kPa, with a median stiffness of the hilum of 6.5 kPa. Testis with hydrocele recorded higher values (parenchyma: 5.4 kPa; hilum: 7.0 kPa), and the cases of varicocele were found to be less stiff (parenchyma: 3.2 kPa; hilum: 4.3 kPa). Since atrophied testis and those corresponding to scrotal infection were observed, the hilum stiffness was exceptionally high. In sum, hilum values were shown to be higher than parenchymal values in all groups. SWE offers a reproducible, measurable measurement of testicular tissue stiffness and its distinction of normal or abnormal tissue. Normative SWE values would create an accurate diagnosis that helps it be cost-effective and used as a good adjunct in the assessment of scrotal ultrasound examination.
Shear Wave Elastography (SWE), Testicular Imaging, Tissue Stiffness, Ultrasound, Scrotal Abnormalities.